{"product_id":"osi-vascular-imaging-table","title":"US Imaging Tables 9650FL4XT V.A.C.S. C-Arm Imaging Table","description":"\u003ch2 data-end=\"272\" data-start=\"207\" data-section-id=\"1eojudb\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"270\" data-start=\"210\"\u003eUS Imaging Tables 9650FL4XT V.A.C.S. C-Arm Imaging Table\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-end=\"377\" data-start=\"273\"\u003e\u003cstrong data-end=\"377\" data-start=\"273\"\u003eVascular \/ Angiographic \/ Cardiac \/ Surgical (V.A.C.S.) Table | 4-Way Float Top with Extended Travel\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-end=\"382\" data-start=\"379\"\u003e\n\u003ch3 data-end=\"408\" data-start=\"384\" data-section-id=\"miz626\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"408\" data-start=\"388\"\u003eProduct Overview\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-end=\"830\" data-start=\"410\"\u003eThe \u003cstrong data-end=\"460\" data-start=\"414\"\u003eUS Imaging Tables 9650FL4XT V.A.C.S. Table\u003c\/strong\u003e is a high-performance \u003cstrong data-end=\"506\" data-start=\"483\"\u003eC-arm imaging table\u003c\/strong\u003e designed for \u003cstrong data-end=\"597\" data-start=\"520\"\u003evascular, angiographic, cardiac, surgical, and pain management procedures\u003c\/strong\u003e. Built with a \u003cstrong data-end=\"655\" data-start=\"612\"\u003efully radiolucent carbon fiber tabletop\u003c\/strong\u003e and extended cantilever design, this table allows for \u003cstrong data-end=\"771\" data-start=\"710\"\u003efull-body fluoroscopic imaging without metal interference\u003c\/strong\u003e, making it ideal for advanced interventional environments.\u003c\/p\u003e\n\u003cp data-end=\"1088\" data-start=\"832\"\u003eAs part of the V.A.C.S. (Vascular\/Angiographic\/Cardiac\/Surgical) series, this model features a \u003cstrong data-end=\"975\" data-start=\"927\"\u003e4-way floating tabletop with extended travel\u003c\/strong\u003e, delivering exceptional positioning flexibility and workflow efficiency. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-end=\"1093\" data-start=\"1090\"\u003e\n\u003ch3 data-end=\"1127\" data-start=\"1095\" data-section-id=\"1erbrxc\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"1127\" data-start=\"1099\"\u003eKey Features \u0026amp; Movements\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-end=\"2148\" data-start=\"1129\"\u003e\n\u003cli data-end=\"1241\" data-start=\"1129\" data-section-id=\"7o6utz\"\u003e\n\u003cstrong data-end=\"1174\" data-start=\"1131\"\u003eMotorized Height Adjustment (Up \/ Down)\u003c\/strong\u003e\n\u003cul data-end=\"1241\" data-start=\"1179\"\u003e\n\u003cli data-end=\"1241\" data-start=\"1179\" data-section-id=\"9kozpc\"\u003eSmooth elevation for patient access and ergonomic workflow\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1367\" data-start=\"1243\" data-section-id=\"eieai6\"\u003e\n\u003cstrong data-end=\"1291\" data-start=\"1245\"\u003eTrendelenburg \u0026amp; Reverse Trendelenburg Tilt\u003c\/strong\u003e\n\u003cul data-end=\"1367\" data-start=\"1296\"\u003e\n\u003cli data-end=\"1367\" data-start=\"1296\" data-section-id=\"1e43p56\"\u003ePrecise table angulation for vascular and interventional procedures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1461\" data-start=\"1369\" data-section-id=\"vy1xrm\"\u003e\n\u003cstrong data-end=\"1407\" data-start=\"1371\"\u003eLateral Tilt (Left \/ Right Roll)\u003c\/strong\u003e\n\u003cul data-end=\"1461\" data-start=\"1412\"\u003e\n\u003cli data-end=\"1461\" data-start=\"1412\" data-section-id=\"uxm863\"\u003eImproves imaging angles and procedural access\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1722\" data-start=\"1463\" data-section-id=\"1h22o4r\"\u003e\n\u003cstrong data-end=\"1518\" data-start=\"1465\"\u003e4-Way Floating Tabletop (FL4XT – Extended Travel)\u003c\/strong\u003e\n\u003cul data-end=\"1722\" data-start=\"1523\"\u003e\n\u003cli data-end=\"1567\" data-start=\"1523\" data-section-id=\"fws1fr\"\u003e\u003cstrong data-end=\"1565\" data-start=\"1525\"\u003eLongitudinal movement (head-to-foot)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-end=\"1609\" data-start=\"1570\" data-section-id=\"1dyo8k2\"\u003e\u003cstrong data-end=\"1607\" data-start=\"1572\"\u003eLateral movement (side-to-side)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-end=\"1665\" data-start=\"1612\" data-section-id=\"rjpjil\"\u003eManual float top with precision locking mechanism\u003c\/li\u003e\n\u003cli data-end=\"1722\" data-start=\"1668\" data-section-id=\"ctf7mf\"\u003eExtended travel range for maximum imaging coverage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1886\" data-start=\"1724\" data-section-id=\"g4djtt\"\u003e\n\u003cstrong data-end=\"1781\" data-start=\"1726\"\u003eOptional Motorized Longitudinal Drive (if equipped)\u003c\/strong\u003e\n\u003cul data-end=\"1886\" data-start=\"1786\"\u003e\n\u003cli data-end=\"1886\" data-start=\"1786\" data-section-id=\"rxf7di\"\u003ePowered tabletop movement for enhanced positioning control \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2043\" data-start=\"1888\" data-section-id=\"1pgxq0r\"\u003e\n\u003cstrong data-end=\"1927\" data-start=\"1890\"\u003eRadiolucent Carbon Fiber Tabletop\u003c\/strong\u003e\n\u003cul data-end=\"2043\" data-start=\"1932\"\u003e\n\u003cli data-end=\"2043\" data-start=\"1932\" data-section-id=\"1glj2ok\"\u003eLarge cantilevered imaging area for \u003cstrong data-end=\"2003\" data-start=\"1970\"\u003efull C-arm access head-to-toe\u003c\/strong\u003e \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2148\" data-start=\"2045\" data-section-id=\"7724x2\"\u003e\n\u003cstrong data-end=\"2075\" data-start=\"2047\"\u003eMemory Position Controls\u003c\/strong\u003e\n\u003cul data-end=\"2148\" data-start=\"2080\"\u003e\n\u003cli data-end=\"2148\" data-start=\"2080\" data-section-id=\"pqfga5\"\u003eStore and recall frequently used positions for improved workflow\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"2153\" data-start=\"2150\"\u003e\n\u003ch3 data-end=\"2185\" data-start=\"2155\" data-section-id=\"1es7z0e\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"2185\" data-start=\"2159\"\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-end=\"2537\" data-start=\"2187\"\u003e\n\u003cli data-end=\"2211\" data-start=\"2187\" data-section-id=\"1nno82t\"\u003e\n\u003cstrong data-end=\"2199\" data-start=\"2189\"\u003eModel:\u003c\/strong\u003e 9650FL4XT\u003c\/li\u003e\n\u003cli data-end=\"2287\" data-start=\"2212\" data-section-id=\"w0iyur\"\u003e\n\u003cstrong data-end=\"2229\" data-start=\"2214\"\u003eTable Type:\u003c\/strong\u003e V.A.C.S. (Vascular \/ Angiographic \/ Cardiac \/ Surgical)\u003c\/li\u003e\n\u003cli data-end=\"2337\" data-start=\"2288\" data-section-id=\"1xjiho\"\u003e\n\u003cstrong data-end=\"2303\" data-start=\"2290\"\u003eTabletop:\u003c\/strong\u003e Carbon fiber, fully radiolucent\u003c\/li\u003e\n\u003cli data-end=\"2395\" data-start=\"2338\" data-section-id=\"vxht4o\"\u003e\n\u003cstrong data-end=\"2351\" data-start=\"2340\"\u003eDesign:\u003c\/strong\u003e Cantilevered for unobstructed fluoroscopy\u003c\/li\u003e\n\u003cli data-end=\"2446\" data-start=\"2396\" data-section-id=\"1c5jzou\"\u003e\n\u003cstrong data-end=\"2411\" data-start=\"2398\"\u003eMobility:\u003c\/strong\u003e Mobile base with locking casters\u003c\/li\u003e\n\u003cli data-end=\"2537\" data-start=\"2447\" data-section-id=\"5wt0vr\"\u003e\n\u003cstrong data-end=\"2459\" data-start=\"2449\"\u003ePower:\u003c\/strong\u003e 110V or 220V configurations available \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"2542\" data-start=\"2539\"\u003e\n\u003ch3 data-end=\"2573\" data-start=\"2544\" data-section-id=\"2mt5a8\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"2573\" data-start=\"2548\"\u003eClinical Applications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-end=\"2818\" data-start=\"2575\"\u003e\n\u003cli data-end=\"2617\" data-start=\"2575\" data-section-id=\"1nnbvyo\"\u003e\u003cstrong data-end=\"2615\" data-start=\"2577\"\u003eVascular \u0026amp; Endovascular Procedures\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-end=\"2656\" data-start=\"2618\" data-section-id=\"cy6mez\"\u003e\u003cstrong data-end=\"2654\" data-start=\"2620\"\u003eCardiac \u0026amp; Angiographic Imaging\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-end=\"2694\" data-start=\"2657\" data-section-id=\"leorvi\"\u003e\u003cstrong data-end=\"2692\" data-start=\"2659\"\u003eFluoroscopy-Guided Procedures\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-end=\"2740\" data-start=\"2695\" data-section-id=\"1n4wfh8\"\u003e\u003cstrong data-end=\"2738\" data-start=\"2697\"\u003ePain Management \u0026amp; Spine Interventions\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-end=\"2773\" data-start=\"2741\" data-section-id=\"1rn6uks\"\u003e\u003cstrong data-end=\"2771\" data-start=\"2743\"\u003eInterventional Radiology\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-end=\"2818\" data-start=\"2774\" data-section-id=\"11y94k1\"\u003e\u003cstrong data-end=\"2818\" data-start=\"2776\"\u003eOutpatient Surgery Centers \u0026amp; Hospitals\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"2823\" data-start=\"2820\"\u003e\n\u003ch3 data-end=\"2873\" data-start=\"2825\" data-section-id=\"1mdfrne\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"2873\" data-start=\"2829\"\u003eWhy Choose the 9650FL4XT V.A.C.S. Table?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-end=\"3224\" data-start=\"2875\"\u003eThe \u003cstrong data-end=\"2903\" data-start=\"2879\"\u003eUS Imaging 9650FL4XT\u003c\/strong\u003e is engineered for \u003cstrong data-end=\"2987\" data-start=\"2922\"\u003emaximum imaging access, precision positioning, and durability\u003c\/strong\u003e, making it a top choice for facilities requiring advanced \u003cstrong data-end=\"3073\" data-start=\"3046\"\u003eC-arm table performance\u003c\/strong\u003e. Its extended travel floating top and multi-axis motion capabilities allow clinicians to position patients accurately without repositioning the C-arm.\u003c\/p\u003e\n\u003cp data-end=\"3252\" data-start=\"3226\"\u003eFacilities benefit from:\u003c\/p\u003e\n\u003cul data-end=\"3492\" data-start=\"3253\"\u003e\n\u003cli data-end=\"3306\" data-start=\"3253\" data-section-id=\"1sv4910\"\u003eFull-body fluoroscopic access without obstruction\u003c\/li\u003e\n\u003cli data-end=\"3352\" data-start=\"3307\" data-section-id=\"15hzi4g\"\u003eMulti-directional positioning flexibility\u003c\/li\u003e\n\u003cli data-end=\"3392\" data-start=\"3353\" data-section-id=\"1quaia8\"\u003eSmooth, stable operation under load\u003c\/li\u003e\n\u003cli data-end=\"3438\" data-start=\"3393\" data-section-id=\"c6j048\"\u003eHigh-quality carbon fiber imaging surface\u003c\/li\u003e\n\u003cli data-end=\"3492\" data-start=\"3439\" data-section-id=\"b27hmp\"\u003eProven reliability in interventional environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"US Imaging Tables","offers":[{"title":"Default Title","offer_id":47730284626074,"sku":null,"price":9900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0314\/9549\/files\/2586b424-f0ac-490a-b9a7-c9b1b9db3516.jpg?v=1775853387","url":"https:\/\/www.incav.com\/products\/osi-vascular-imaging-table","provider":"inCAV Medical Imaging Equipment","version":"1.0","type":"link"}